Search:




User name:

Password:



FIRE ALARM
Addressable
Conventional
Wireless
   
   
 
 
WIRELESS COMMANDER
WIRELESS EMERGENCY ALARM SYSTEM
Price List
Order Status


   
Addressable Fire Alarm System

A Fire Alarm System is designed to detect the presence of fire by monitoring the environmental changes and to provide an early warning of fire that will notify people to evacuate and take action to stop the fire. Airlight’s addressable intelligent fire alarm systems respond rapidly to incipient fire signatures with unmatched precision maximizing speed, stability and reliability.

In case of fire, the respective area detector senses the fire and sends the data of fire and initiating device’s address to the control panel. On receipt of the signal, the control panel display shows the exact zone number, zone location, device number and device location. The panel also sends signal to respective Sounder beacon (to give audible & visual alarm), fire fighting systems, HVAC tripping etc.

In an addressable system, devices are wired in a loop around the building with each device having its own unique 'address'. The system may contain one or more loops depending upon the size of the system and design requirements. Airlight’s one cable addressable fire alarm system works on 24 volts DC which is drawn from main control panel through a single cable (2 core). The digital communication signals between the fire alarm control panel and the initiating (Eg: Smoke detector, Heat detector, Multisensor, etc) & notification (Eg: Sounder beacon) devices are transferred through the same cable using power line communication technique. This system can also be seamlessly integrated with AHU, AC supply, Access Control system, BMS, etc.


Addressable Intelligent Optical Smoke Detector - AA103SD

This detector is designed to detect the smoke and provide the smoke level in their detection area.It communicates the analogue value of the smoke,alarm status,contamination level and existance with the loop to the control panel.Also it allows the control panel to change its sensitivity,address,isolation,test,etc.This detector is suitable to provide an early response  to a wide range of slow burning smouldering fires.


Learn More        
Addressable Intelligent Heat Detector - AA103HD

This detector is designed to detect the high temperature caused by fire. It provides the thermal level in their detection area and communicates the analogue value of the thermal level,alarm status,existance with loop to the control panel.Also it allows the control panel to change its sensitivity, address,isolation,test,etc.These detectors are intended for indoor use and in dry premises.


Learn More        
Addressable Intelligent Multisensor - AA103MD

This detector is designed to detect smoke/thermal level in their detection area.It communicates the analogue value of the smoke/heat,alarm status, contamination level,existence with the loop to the control panel.Also it allows the control panel to change its sensitivity,address,isolation, test,etc.This detector is suitable to provide an early response to a wide range of slow burning smoldering fires.


Learn More        
Addressable Manual Call Point - AA103CP

This device is designed to trigger an alarm manually in case of fire.It communicates the alarm status,existence with the loop to the control panel.Also it allows the control panel to change its address,isolation,test,etc.


Learn More        
Addressable Loop Powered Sounder Beacon - AA103SB

This AA103SB Addressable Loop Powered Sounder Beacon is designed to provide audio visual alarm for fire warning. The device’s unique ID(address) makes it possible for the control panel to trigger an alarm or silence as programmed and enable to change its address, isolation, test, etc.This sounder beacon unit comes along with a sounder head and a base.


Learn More        
Addressable 3 Wire Sounder Beacon - AA103SB3

This AA103SB3 Addressable 3 Wire Sounder Beacon is designed to provide audio visual alarm for fire warning. This unit will be useful to reduce loop load in those systems where loop current requirements are excessive. Power for this unit is directly taken from control panel with the use of one extra wire.The device's unique ID(address) makes it possible for the control panel to trigger an alarm or silence as programmed and enables to change its address, isolation, test, etc.This sounder beacon unit comes along with a sounder head and a base.


Learn More        
Addressable Wireless Input Interface Unit - AW103IM

This device is designed to receive the signal from input devices like wireless detectors,MCP's and communicates to the control panel.This device is connected on SLC loop of control panel.


Learn More        
Addressable Wireless Output Interface Unit - AW103OM

 This device is designed to transmit the signal to output devices like wireless sounders,Relay unit and communicates from the control panel.This device is connected on SLC loop of control panel.


Learn More        
Addressable Wireless 3 Wire Input Interface Unit - AW103IM3

 This device is designed to receive the signal from input devices like wireless detectors,MCP’s and communicates to the control panel.This device is connected on SLC loop of control panel.In systems where loop current requirements are excessive this unit will be useful to reduce loop load.Power for this unit is directly taken from control panel by using one extra wire.


Learn More        
Addressable Short Circuit Isolator - AA103SCI

This device is designed to provide short circuit protection,for SLC loop wiring. In the event of a short circuit,isolators disconnect only the section of cable between the two isolators,located electrically closest to the fault.Devices outside the disconnected section continue to operate normally.


Learn More        
Addressable Single Input/Output Module - AA103SIO

This device is designed to act as an interface unit for contact devices (normally open)like waterflow switch, pressure switch, etc.,and to provide dry relay contact to control external appliances such as door closers, fans, dampers, etc., It communicates the contact status, existence with the loop to the control panel. It also allows the control panel to change its address, isolation, test, etc.


Learn More        
Addressable Monitor Module - AA103MM

This device is designed to act as an interface unit for contact devices(normally open) like waterflow switch,pressure switch,etc., to control panel.It communicates the contact status, existence with the loop to the control panel.It also allows the control panel to change its address, isolation,test,etc.


Learn More        
Addressable Control Module - AA103CM

This device is designed to provide dry relay contact to control external appliances such as door closers,fans,dampers,etc.,It communicates the contact status,existence with the loop to the control panel.It also allows the control panel to change its address, isolation,test,etc.


Learn More        
Addressable Gas Leak Detector -  AA103LPG

This Addressable Gas Leak Detector is designed for detecting and early warning of gas leaks and to be used with Airlight alarm panel.The detector is made up of an Electrochemical Gas Sensor housing united with a latest microprocessor.The detecotr can send alarm condition message to the alarm panel using ALAA2XV1 technology. The entire unit is housed in sleek,compact,aesthetic poly-carbonate enclosure.

Learn More        
 
Addressable Weather Proof Manual Call Point - ALAMCW601

The unit is provided with pushbutton actuator with a mushroom head. The actuator is in contact with the glass cover, which when broken the internal contacts closes. When internal contact closes, built-in addressable module sets the alarm flag in on-board memory. Control panel collects these data at regular intervals along with its address for central processing. The panel then sends signal to respective sounders beacons to begin evacuation. The unit is provided with a large gasket for weather protection.or weather protection.


Learn More        
Addressable Flame Proof Manual Call Point - ALAMCF601

The unit is provided with push button actuator with a mushroom head. The actuator is in contact with the glass cover, which when broken the internal contacts closes. When internal contact closes, built-in addressable module sets the alarm flag in on-board memory. Control panel collects these data at regular intervals along with its address for central processing. The panel then sends signal to respective sounders beacons to begin evacuation. The unit is provided with a large gasket for weather protection. ther protection.


                    Learn More        
Intelligent Addressable Fire Alarm Control Panel - AA103FP

The AA103 series Addresable control panel provides superior features with greater information capacity and convenience.The AA103FP control panels offer great functionality in receiving information from the surrounding sensors,displaying the details of detection and also communicates the status to the output devices.This panel is equipped with a colour TFT display with touch-screen interface making it more user friendly.






Learn More        
 
Addressable Intelligent Repeater Panel - AA103RP

Designed to provide a cost-effective platform for a fire alarm system annunciation; duplicating the same information as the main control panel, but at a remote location. The panel offers system designers and end users a technically sophisticated range of facilities and functions whilst maintaining ease of programming, installation, and operation. The repeater panel has same lamps and text display as the main control panel but no device circuits can be connected. The AA103RP is a new force in high level annunciation for a wide range of premises/systems. can be connected. The AA103RP is a new force in high level annunciation for a wide range of premises/systems.


Learn More        
Airlight Graphics Software - AL103GRS

Designed to be integrated with fire alarm system to provide clear & precise real-time information of alarm on PC work station with use of text, floor & map. The graphics software makes it easy for the user to locate affected area to enable them to make efficient response to emergency by constantly monitoring incoming alarm/trouble data. In case of alarm/trouble the particular floor plan will pop-up automatically and the respective triggered device will flash with change of colour & will provide clear text message of zone no., device no. and description of device location. The software also has a password protection feature that allows only authorized personnel to login/logout/change password.


Learn More        

© Copyright 2010 - 2011.   Naveen Alarm Systems India Pvt Ltd.